PCV0.S10 VALVE SERIES
SAE Cartridge - 350 bar
Pressure compensator
Priority on demand
DESCRIPTION
The PCV is a screw-in, cartridge style, priority- on-demand, pressure compensator with a static load sense. The valve delivers
required priority flow (0 to max. available) on demand to 4 regardless of load pressure; inlet flow is at 3. In idle position, the valve will
deliver all input flow at 3 to the priority port 4. Increasing pressure at 4 (applied to the spool against the spring force) will result in an
increasing excess flow exit at 2 (by-pass of input flow). Excess flow at 2 can be used for auxiliary functions. Port 1 is the load sense
pressure port. Pressure at 1 assists the spring and moves the spool back so priority flow is supplied.
Cavity
HYDRAULIC SYMBOL
Cross section
SAE10-3
TECHNICAL DATA
EXTERNAL COMPONENT TREATMENT
Zn/Fe - standard (96h)
Zn/Ni (720h) (Upon customer request)
MAXIMUM FLOW
45 l/min
MAXIMUM OPERATING PRESSURE
350 bar
WEIGHT
0,186 kg
SEAL KIT CODE
SK.103 (standard sealing NBR-BUNA-N)
OIL TESTING CONDITIONS
ISO VG 46 cSt
ORIENTATION
No restrictions
INSTALLATION TORQUE
60-70 Nm
FILTRATION
20/18/15 ISO 4406 (maximum filtration admitted)
VISCOSITIES
7,4 to 420 cSt
FLUIDS
Mineral - based or synthetics with lubricating properties
OIL TEMPERATURE RANGE
-30° C to 110° C
O-RING TEMPERATURE RANGE
-30° C to 110° C (standard sealing NBR - BUNA - N)
-35° C to 140° C (HNBR - Upon customer request)
-23° C to 225° C (FKM - Upon customer request)
Hex.24
MAXIMUM PRIORITY FLOW
35 l/min with 5,5 bar compensator spring
± 15% for 10,3 bar compensator spring
COMPENSATOR SPRING ACCURACY
± 20% for 5,5 bar compensator spring
P C V 0
.
ORDERING CODE
S 1 0 0
*
. .
0 0 0
Valve basic code
7/8-14 UNF with Ø19,05 and Ø17,47 and
Ø15,87 nose sizes
Size
Marking
0 = Standard factory marking.
Customized marking can be done
upon request.
000 = Standard configuration.
Spring model
code
Static LS pressure
(bar)
N 5,5
B 10,3
Bias Spring Options
PRESSURE COMPENSATOR
Specifications may change without notice.
1 2
PRESSURE COMPENSATOR
3 4
SPRING B
Flow (l/min)
Load pressure (bar) Priority > BypassPriority < Bypass
SPRING N
Load pressure (bar)
Flow (l/min)
Priority < Bypass Priority > Bypass
PCV0.S10
The performance chart illustrates flow handling capacity 3 to 4 and 3 to 2 and
the trace of the priority flow at different values vs. load pressure.
p/Q curves are recorded at TOil = 40°C and 46 cSt.
SPRING B
Legend
3vs2
3vs4
Load pressure (bar)
Flow (l/min)
Legend
3vs2
3vs4
SPRING N
Load pressure (bar)